How researchers measure activity in neural organoids

Published in Brain Activity, Brain/Neurology, Journals, Tools.

November 10, 2026

In a review published November 2, 2026, in Nature Reviews Bioengineering, Cynthia Lo, Ferdi Ridvan Kiral and In-Hyun Park compare tools for measuring electrical activity in lab-grown neural organoids. The review looks at what researchers can learn from individual cells, groups of cells and entire networks.

Patch-clamp recordings can show how an individual cell responds to stimulation. Optical techniques use fluorescent signals linked to calcium or voltage to observe activity across many cells. Electrode arrays record extracellular electrical signals at multiple locations, allowing researchers to examine when different parts of an organoid fire together.

The authors argue that describing an organoid as simply active or inactive misses differences in how its network behaves. The review also discusses how organoid health and contact between tissue and electrodes can affect recordings. These tools help scientists study neural development in the lab; measuring activity alone does not establish that an organoid reproduces the function of a human brain.

Source: Lo, Kiral and Park, Nature Reviews Bioengineering, November 2, 2026.